Files
geedge-jira/md/OMPUB-499.md
2025-09-14 21:52:36 +00:00

134 lines
3.9 KiB
Markdown
Raw Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

# 【E21现场】MWV-IGW站点断电重启之后链路切为bypass无法切为inline
| ID | Creation Date | Assignee | Status |
|----|----------------|----------|--------|
| OMPUB-499 | 2022-05-29T19:41:06.000+0800 | 陆秋文 | 已关闭 |
---
2022-05-29 MWV-IGW   /MWV-GGSN 站点断电恢复设备重启之后OPD光衰链路正常但是SMBIO上无法手动将链路切为inline切inline失败。为此墨处打电话要求今天必须远程处理问题。
该问题在2022-05-06 MWV-IGW 出现过当时根据现场情况日志定位出的故障原因是设备断电重启之后出现SMBIO交换芯片识别不了。厂商认为是SMBIO电池没电导致的。
 
临时修复办法是:
1、reboot SMBIO 待重启成功之后查看SMBIO和NPB之间的保活状态。
    show portgroup  all  detail   
    保活状态都显示offline
2、因保活状态都是online 所以登录NPB查看网卡没有收到流量重启驱动mrcpd。
3、重启驱动之后重新查看保活状态是否切为inline。
4、待所有NPB保活切为inline登录SMBIO再次尝试将链路状态切为inline。
 
根据以上临时处理办法指导墨处远程处理目前链路已切为inline。
具体问题原因,给墨处的回复是待明天我现场再次查看后回复,
 
明天是否可以给墨处解释断电恢复后链路无法直接切为inline的原因怀疑是SMBIO电池没电导致申请去MWV-IGW站点现场定位和查看解决带上万用表和新的电池
另,此次临时处理步骤,墨处要求给写个文档。
 
针对该站点电力断电问题,墨处已联系运营商,电力故障原因不明。**luqiuwen** commented on *2022-05-30T09:49:40.192+0800*:
[~zhengchao] 此问题以前出现过具体表现为设备断电再加电SMBIO的交换芯片无法挂载整机业务中断。厂商给的解释是主板上的电池没电。电池的电压无法通过板载传感器获取只能到现场拆下电池后使用万用表测量电池电压以确定厂商的说法是否可靠。
现在有以下几个问题需要决策:
* 如何向用户解释该问题出现的原因?
* 能否申请前往MWV-IGW站点检查电池电压
* 业主要求的临时解决方案文档是否能够提供,这一部分的操作,在我们已有的文档中没有体现。
---
**zhengchao** commented on *2022-05-30T11:21:39.991+0800*:
如实和用户描述问题,但话不要说死,强调{*}推测{*}由于机房断电 -> SMBIO电池耗尽 -> 导致SMBIO加载出现问题。
关于解决方案文档,可以提供给用户。
{quote}After a power cutoff, there may be a rare case that the appliance can not be switched to inline mode. Please operate as following steps to try to recover.
{quote}
---
**luqiuwen** commented on *2022-05-30T14:09:59.297+0800*:
[~liuju] 请帮忙提供故障现象截图以便在TSG 9140 Hardware Installation and Configuration中增补对应的内容。
---
**liuju** commented on *2022-05-30T14:39:44.038+0800*:
收到,好的,明白了~
---
**luqiuwen** commented on *2022-05-31T16:07:39.189+0800*:
据[~liuju] 反馈MWV-IGW的SMBIO和SMBCX板卡上电池的电压为
|| ||电池1||电池2||
|SMBIO|0.06V|0.89V|
|SMBCX|0.01V|——|
均远低于正常值2.8V。更换电池后,故障现象消失。可以确认该问题出现的直接原因为板卡电池电量耗尽。
---
**luqiuwen** commented on *2022-09-15T15:14:26.801+0800*:
现场人员更换了电池,未给出类似问题的报告,关闭该问题。
---
## Attachments
**28321/微信图片_20220530141419.png**
---
**28322/微信图片_20220530141427.png**
---
**28323/微信图片_20220530141432.png**
---
**28324/微信图片_20220530141438.png**
---
**28325/微信图片_20220530141444.png**
---
**28326/微信图片_20220530141453.png**
---