# 为测试推荐网络拓扑现申请修改光保设备与研发组3300后插板接线
| ID | Creation Date | Assignee | Status |
|----|----------------|----------|--------|
| OMPUB-221 | 2021-09-02T14:26:40.000+0800 | 栗文 | 完成 |
---
为测试推荐网络拓扑现申请修改光保设备中3号子卡与研发组3300后插板接线具体连接方式如下
如下图所示Internal Router与光保设备中3号子卡的R3 T3接口连接光保3号子卡的R1 T1接入9000-SMBRTM-32XE设备指定链路组中的Internal类型的端口*Eth-10G-1/5/1**端口1号端口*9000-SMBRTM-32XE设备同链路组中的External类型的端口*Eth-10G-1/5/0**端口0号端口*接到光保设备的R2 T2最后将光保设备的T4 R4 与External Router对应端口连接。
!image-2021-09-02-14-26-16-156.png!**liwen** commented on *2021-09-06T11:18:43.080+0800*:
已将连线调整为图片连线方式
---