# 【E21-OLAP】绘制E21现场OAP-PE及Bole-PE站点火焰图
| ID | Creation Date | Assignee | Status |
|----|----------------|----------|--------|
| OMPUB-368 | 2022-02-16T17:19:23.000+0800 | 刘菊 | 完成 |
---
OAP-PE及Bole-PE目前存在Flink Taskmanager容器内存占用偏高现象需要绘制火焰图辅助故障定位。
操作步骤:
1登录10.229.12.4、10.231.12.4
2将软件上传至服务器,并解压。
3将软件包传入taskmanager容器内。
docker cp async-profiler-2.7-linux-x64 taskmanager:/opt/
4进入容器
docker exec -it taskmanager /bin/bash
查看taskmanager pid。
ps -ef |grep taskmanager
5:绘制火焰图
cd /opt/async-profiler-2.7-linux-x64
./profiler.sh -d 30 -e itimer -f 【站点名称】-taskmanager.html pid
执行后会在当前目录生成【站点名称】-taskmanager.html文件
6:退出容器将文件复制到服务器
exit
docker cp taskmanager:/opt/async-profiler-2.7-linux-x64/【站点名称】-taskmanager.html ./
 **liuju** commented on *2022-02-16T20:35:59.614+0800*:
已上传到附件。
---