# Niagara 2825状态切换为bypass后没有切回inline
|
||||
|
||||
| ID | Creation Date | Assignee | Status |
|
||||
|----|----------------|----------|--------|
|
||||
| OMPUB-1014 | 2023-09-04T14:21:02.000+0800 | 陆秋文 | 已解决 |
|
||||
|
||||
|
||||
---
|
||||
|
||||
2023.9.2 18:50(UTC+8)左右ahamson反馈MSH-TSGX-02流量降低(从120Gbps降低到60Gbps)见图1,经查对应光保(10.10.20.121)一条链路状态为down见图2,查看光保日志发现其当天最后一次切bypass后没有切回inline。**luqiuwen** commented on *2023-09-07T13:34:41.765+0800*:
|
||||
|
||||
已调整该Segment的保活间隔为50ms,切bypass的阈值为10次。调整后此问题未出现。
|
||||
|
||||
|
||||
|
||||
---
|
||||
|
||||
|
||||
|
||||