# 福建项目:泉州移动5G sapp频繁重启
|
|||
|
|
|
|||
|
|
| ID | Creation Date | Assignee | Status |
|
|||
|
|
|----|----------------|----------|--------|
|
|||
|
|
| OMPUB-901 | 2023-04-17T10:27:55.000+0800 | 杨威 | 已解决 |
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
IP:192.168.13.5、6
|
|||
|
|
|
|||
|
|
重启频率:10-20min重启一次
|
|||
|
|
|
|||
|
|
gdb截图
|
|||
|
|
!image-2023-04-17-10-27-20-742.png|thumbnail!
|
|||
|
|
!image-2023-04-17-10-27-26-454.png|thumbnail! **zhangzhihan** commented on *2023-04-17T10:28:27.676+0800*:
|
|||
|
|
|
|||
|
|
4.11日关闭sip,dtls,fw_dtls,fw_voip插件后不重启
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**yangwei** commented on *2023-05-15T09:42:00.656+0800*:
|
|||
|
|
|
|||
|
|
在两台NPB上分别仅关闭DTLS和VoIP进行对比测试,结果显示,仅关闭DTLS的NPB未出现频繁重启的现象,推测原因为DTLS插件导致。
|
|||
|
|
|
|||
|
|
福建现场的DTLS解析层版本较低(1.0.1),已提供1.0.10版本。
|
|||
|
|
|
|||
|
|
此外,DTLS插件正在重构,预计22.06版本提供重构后版本,当前版本建议暂时关闭该功能。
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|