34 lines
791 B
Markdown
34 lines
791 B
Markdown
|
|
# Niagara 2825状态切换为bypass后没有切回inline
|
|||
|
|
|
|||
|
|
| ID | Creation Date | Assignee | Status |
|
|||
|
|
|----|----------------|----------|--------|
|
|||
|
|
| OMPUB-1014 | 2023-09-04T14:21:02.000+0800 | 陆秋文 | 已解决 |
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
2023.9.2 18:50(UTC+8)左右ahamson反馈MSH-TSGX-02流量降低(从120Gbps降低到60Gbps)见图1,经查对应光保(10.10.20.121)一条链路状态为down见图2,查看光保日志发现其当天最后一次切bypass后没有切回inline。**luqiuwen** commented on *2023-09-07T13:34:41.765+0800*:
|
|||
|
|
|
|||
|
|
已调整该Segment的保活间隔为50ms,切bypass的阈值为10次。调整后此问题未出现。
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
## Attachments
|
|||
|
|
|
|||
|
|
**43767/光保日志.txt**
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**43769/图1MSH-02流量降低.jpg**
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**43768/图2光保一条链路down.jpg**
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|