# 【E21现场】MWV-IGW站点断电重启之后,链路切为bypass,无法切为inline
|
|||
|
|
|
|||
|
|
| ID | Creation Date | Assignee | Status |
|
|||
|
|
|----|----------------|----------|--------|
|
|||
|
|
| OMPUB-499 | 2022-05-29T19:41:06.000+0800 | 陆秋文 | 已关闭 |
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
2022-05-29 MWV-IGW /MWV-GGSN 站点断电恢复,设备重启之后,OPD光衰链路正常,但是SMBIO上无法手动将链路切为inline,切inline失败。为此墨处打电话要求今天必须远程处理问题。
|
|||
|
|
|
|||
|
|
该问题在2022-05-06 MWV-IGW 出现过,当时根据现场情况日志定位出的故障原因是:设备断电重启之后出现SMBIO交换芯片识别不了。厂商认为是SMBIO电池没电导致的。
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
临时修复办法是:
|
|||
|
|
|
|||
|
|
1、reboot SMBIO ,待重启成功之后,查看SMBIO和NPB之间的保活状态。
|
|||
|
|
|
|||
|
|
show portgroup all detail
|
|||
|
|
|
|||
|
|
保活状态都显示offline
|
|||
|
|
|
|||
|
|
2、因保活状态都是online ,所以登录NPB,查看网卡没有收到流量,重启驱动mrcpd。
|
|||
|
|
|
|||
|
|
3、重启驱动之后,重新查看保活状态是否切为inline。
|
|||
|
|
|
|||
|
|
4、待所有NPB保活切为inline,登录SMBIO再次尝试将链路状态切为inline。
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
根据以上临时处理办法,指导墨处远程处理,目前链路已切为inline。
|
|||
|
|
|
|||
|
|
具体问题原因,给墨处的回复是待明天我现场再次查看后回复,
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
明天是否可以给墨处解释断电恢复后链路无法直接切为inline的原因怀疑是SMBIO电池没电导致,申请去MWV-IGW站点现场定位和查看解决(带上万用表和新的电池)。
|
|||
|
|
|
|||
|
|
另,此次临时处理步骤,墨处要求给写个文档。
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
针对该站点电力断电问题,墨处已联系运营商,电力故障原因不明。**luqiuwen** commented on *2022-05-30T09:49:40.192+0800*:
|
|||
|
|
|
|||
|
|
[~zhengchao] 此问题以前出现过,具体表现为设备断电再加电,SMBIO的交换芯片无法挂载,整机业务中断。厂商给的解释是主板上的电池没电。电池的电压,无法通过板载传感器获取,只能到现场拆下电池后,使用万用表测量电池电压,以确定厂商的说法是否可靠。
|
|||
|
|
|
|||
|
|
现在有以下几个问题需要决策:
|
|||
|
|
* 如何向用户解释该问题出现的原因?
|
|||
|
|
* 能否申请前往MWV-IGW站点检查电池电压?
|
|||
|
|
* 业主要求的临时解决方案文档是否能够提供,这一部分的操作,在我们已有的文档中没有体现。
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**zhengchao** commented on *2022-05-30T11:21:39.991+0800*:
|
|||
|
|
|
|||
|
|
如实和用户描述问题,但话不要说死,强调{*}推测{*}由于机房断电 -> SMBIO电池耗尽 -> 导致SMBIO加载出现问题。
|
|||
|
|
|
|||
|
|
关于解决方案文档,可以提供给用户。
|
|||
|
|
{quote}After a power cutoff, there may be a rare case that the appliance can not be switched to inline mode. Please operate as following steps to try to recover.
|
|||
|
|
{quote}
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**luqiuwen** commented on *2022-05-30T14:09:59.297+0800*:
|
|||
|
|
|
|||
|
|
[~liuju] 请帮忙提供故障现象截图,以便在TSG 9140 Hardware Installation and Configuration中增补对应的内容。
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**liuju** commented on *2022-05-30T14:39:44.038+0800*:
|
|||
|
|
|
|||
|
|
收到,好的,明白了~
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**luqiuwen** commented on *2022-05-31T16:07:39.189+0800*:
|
|||
|
|
|
|||
|
|
据[~liuju] 反馈,MWV-IGW的SMBIO和SMBCX板卡上电池的电压为
|
|||
|
|
|| ||电池1(左)||电池2(右)||
|
|||
|
|
|SMBIO|0.06V|0.89V|
|
|||
|
|
|SMBCX|0.01V|——|
|
|||
|
|
|
|||
|
|
均远低于正常值2.8V。更换电池后,故障现象消失。可以确认该问题出现的直接原因为板卡电池电量耗尽。
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**luqiuwen** commented on *2022-09-15T15:14:26.801+0800*:
|
|||
|
|
|
|||
|
|
现场人员更换了电池,未给出类似问题的报告,关闭该问题。
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
|
|||
|
|
|
|||
|
|
## Attachments
|
|||
|
|
|
|||
|
|
**28321/微信图片_20220530141419.png**
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**28322/微信图片_20220530141427.png**
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**28323/微信图片_20220530141432.png**
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**28324/微信图片_20220530141438.png**
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**28325/微信图片_20220530141444.png**
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
**28326/微信图片_20220530141453.png**
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|